CNC-cut plastics for underground electrical
Duct bank spacers cut to your layout.
Custom HDPE conduit spacers, separator plates and electrical plastic parts — routed on CNC from your drawing, for electrical contractors, utilities and data center builders.
- 2"–6" conduit, mixed sizes OK
- No mold — no tooling charge
- Saved programs for every phase
What we cut
Plastic parts for the trench, the vault and the data hall.
Spacers are the core of what we do. The same CNC routers cut the rest of the non-conductive plastic an electrical job needs.
Base spacers
Bottom-row spacers with feet that hold the bank off the trench floor so concrete gets underneath.
Duct bankIntermediate spacers
Stacked between rows to keep every conduit on its spacing all the way up the bank.
Duct bankOne-piece grid spacers
The full hole pattern in a single plate — fast to set, no assembling modules in the trench.
Duct bankInterlocking & modular
Single-conduit pieces that lock together into any layout, or stack for tall banks.
Data centerConduit & pipe separator plates
Hole and slot patterns for conduit, cooling pipe and cable separation in data center builds.
TrenchTrench cards & markers
Plastic warning cards and markers set above the bank to flag buried electric before anyone digs.
ElectricalBrackets & mounting plates
Non-conductive mounting plates, standoffs and brackets cut to your equipment drawings.
Anything flatCustom CNC parts
If it starts as plastic sheet and you have a drawing, we can quote it — prototype to production.
Try it
Sketch your spacer in 30 seconds.
Set the conduit size and pattern and see the part take shape. Hit "Quote this layout" and the details drop straight into the quote form.
Layout builder
Sketch your duct bank
Pick the conduit and pattern. The drawing updates as you go — then send it to us with your quote request.
How an order works
Drawing in. Pallets out.
- Send what you have. A drawing, a CAD file, a photo of an old spacer, or just the conduit count and spacing.
- Approve the drawing. We lay out the part — holes, flow-through openings, feet, tie points — and send it back for your OK with pricing.
- We cut and ship. Parts are CNC-routed from solid sheet, deburred, counted, palletized and shipped to your yard or job site.
- Reorder any time. The program is saved. Call with the drawing number and the next phase is identical.
What goes into the program
- Conduit2" – 6" trade size, mixed OK
- PatternRows × conduits per row
- SpacingPer your drawing / spec
- MaterialHDPE (standard), PVC, PP
- ThicknessPer spec — commonly 1/2" to 1"
- FeaturesFeet, flow-through, rebar slots, tie points
- QuantityPrototype to full production
Why CNC-cut plastic
Built for wet concrete and buried conduit.
Non-conductive
Plastic will not carry current, so the spacer adds no path to ground around energized conduit.
Will not rust or rot
HDPE does not corrode, swell or break down in soil, groundwater or concrete.
Exact, every time
Every part comes from the same CNC program, so conduit lines up spacer to spacer down the whole trench.
No tooling cost
Cut from solid sheet — no injection mold — so a custom layout costs the same to set up as a standard one.
Light to handle
Crews carry and set them by hand, and they stack flat on a pallet.
Made for your job
Odd sizes, mixed conduit, tight vault entries — the layout follows your drawing, not a catalog.
Who we work with
Built for the people who set the conduit.
Electrical contractors
Duct banks for commercial, industrial and site work — sized to the bid set.
Utilities & co-ops
Repeat spacer orders for distribution and substation work, held to one spec.
Data center builders
High-count duct banks, separator plates and cooling-pipe supports.
Solar, wind & telecom
Collection-system and fiber duct banks across long runs.
What do you need from me to quote a spacer?
Any of these is enough to start: the project drawing or duct bank detail, a CAD file (DXF, DWG, STEP or PDF), a photo of an existing spacer with a tape measure in it, or just the conduit size, rows, conduits per row and spacing. Add the quantity and the date you need them on site.
Can you match a spacer we already use?
Yes. Send a photo with measurements or ship us a sample. We draw it up, send the drawing back for your OK, and cut to that.
What plastic do you cut spacers from?
HDPE is the standard — it is non-conductive, will not rust or rot, and shrugs off wet concrete and soil. We also cut PVC, polypropylene and lower-cost reprocessed HDPE for big, price-sensitive runs.
Do you handle mixed conduit sizes in one spacer?
Yes. Mixed hole sizes, rebar slots, tie-down points and concrete flow-through openings are all just part of the CNC program.
Can you hold the program for later phases?
Every layout is saved, so phase two, three and four of a project come off the machine identical to phase one. Blanket orders with scheduled releases are welcome.
Do you ship outside South Dakota?
Yes. We ship palletized orders to job sites and yards across the U.S.